Commodity: Hi-Bus KNX 640mA Power Supply Module
Model No.: HKL/D0640412T
Application Scenarios:Office buildings,shopping malls,libraries, convention and exhibition centers and other occasions that require intelligent control of lighting
Product Overview:
providing working voltage for BCU unit. Bus current, bus voltage, and other communication signals can be transmitted and diagnosed through the KNX bus.
Key Features:
Power Supply |
Operating Voltage |
100…264V AC (50/60Hz) |
|
Efficiency |
80% |
Output
|
Number of Dimming Channels |
2 |
|
Model |
HKL/D0640412T |
|
Output Voltage |
30V DC+1/-2V (one is a 30V DC output with carrier communication, and the other is an auxiliary 30V DC output without communication). |
|
Total output current |
640mA |
|
Continuous short-circuit current |
<1.3 A |
Connection
|
EIB/KNX |
EIB bus connection terminals |
|
Load Output |
2 spiral screws to achieve auxiliary power output |
|
Load Input |
3 spiral screws are used to achieve AC power input, and L, N, and E are wired separately. |
KNX Bus Operation and Display |
Key |
Reset restart Key |
|
Key and Red LED |
After pressing the reset and restart Key, the red LED will light up and the bus voltage will be disconnected. After 20 seconds, the power module will reset and work normally. (Note: the voltage of the auxiliary power supply is not affected by the reset). |
Green LED indicator light |
80mA Green LED 320mA Green LED 640mA Green LED |
There are three green LEDs in total, which are used to display the load current of 80mA, 320mA, and 640mA. When the load of the power supply reaches a certain value, the corresponding LED light will light up. |
OLP/PW 2 colors of LED indicator lights |
Green LED Flashing |
Indicates that the power module is working properly |
|
Red LED |
When the power module experiences overload, the red LED lights up for 2 seconds. After 2 seconds, the power module enters a reset and restarts, and the bus voltage is disconnected. Wait for 25 seconds for the reset before the power module retests. If it is still overloaded, repeat the above process; If there is no overload detected, the bus voltage will return to normal. |
Product Protection |
|
Short circuit protection overload protection Overheat protection |
Protection type level |
IP20, EN60 529 |
|
Environmental Temperature |
Operating temperature |
-5 ℃~45 ℃ |
|
Storage temperature |
-25 ℃~55 ℃ |
|
Transportation temperature |
-25 ℃~70 ℃ |
Environmental condition |
Humidity |
no condensation |
Installation Method |
Standard 35mm DIN rail installation |
Installed on a 35mm rail, DIN EN 60 715 |
Dimensions (H*W*D) |
90×72×64 mm |
|
CE Standard |
Complies with EMC standards and low voltage standards |
|
Weight |
0.5KG |
|
Model Selection:
HKL/D0640412T(640mA)
HKL/D0960412T(960mA)
Dimention:
Din rail installation:
Wiring diagram:
Hi-Bus KNX 640mA Power Supply Module